How To Install Windows Server 2003 R2
C H A P T E R 5 |
Windows Server 2003 Operating System Installation
Installing the Operating Arrangement
This department does not provide comprehensive instructions for installing the Windows operating system. This section does provide guidelines for the tasks involved in the OS installation and the installation methods bachelor.
Windows Server 2003 Os Installation Overview
Come across TABLE 5-i for the task map for operating arrangement installation. Perform the tasks in the order given.
Stride | Task | Description | Instructions |
---|---|---|---|
1. | Ready up your server. | Install your server hardware and configure the service processor. | Sun Netra X4250 Server Installation Guide |
2. | Determine the SAS controller. | Configure the hard drives equally required by the SAS controller on‐lath configuration utility. | Chapter 1, "Operating System Installation Overview And Preparation" and Chapter ii, "RAID Configuration" |
iii. | Review the Sun Netra X4250 Server Product Notes. | The product notes contain tardily‐breaking news about the Windows OS software and patches. | Sun Netra X4250 Server Product Notes |
4. | Install the Windows OS. | Choose an installation method and locate the installation instructions. | Windows Server 2003 OS Installation Methods If you lot are using RAID, encounter Installing Windows Server 2003 for a RAID Configuration |
five. | Install the system-specific drivers from the Tools and Drivers DVD. | Install the system-specific drivers needed to run the Windows operating system on the Dominicus Netra X4250 server. | Installing Windows Server 2003 for a RAID Configuration and Installing the Drivers |
6. | Run Windows Update. | Run Windows Update to make sure that you take the latest Microsoft Windows features. | http://update.microsoft.com/microsoftupdate/ |
To Install Windows Server 2003 Using RIS |
-
See the instructions for RIS installation in Appendix B.
To Install the Windows Server 2003 Using Remote KVMS Over IP With Virtual CD-ROM |
This method includes using a remote networked system to install the operating arrangement onto the Sunday Netra X4250 server. The CD or DVD bulldoze of the remote system (virtual CD-ROM) is used to admission the operating system media. The output of the Lord's day Netra X4250 server is displayed on the remote organisation (Remote Panel).
Specific details on the using Remote Console in the Integrated Lights Out Manager (ILOM) can exist found in the Sun Integrated Lights Out Manager 2.0 User's Guide.
Note - This procedure assumes that you are familiar with the ILOM spider web-based interface (spider web GUI) administration. More than information can be found in the Sun Integrated Lights Out Manager 2.0 User's Guide. |
Requirements for Remote Console:
-
Remote organisation connected to the network.
-
One of the following browsers on the remote arrangement – Internet Explorer, Mozilla, or Firefox.
-
CD/DVD drive connected to the remote system.
-
Media for installing the operating organisation of your choice.
-
SP of the Sun Netra X4250 server set as instructed in the Sun Netra X4250 Server Installation Guide.
-
On a remote system, open up a browser and enter the IP address of the ILOM SP for the Sunday Netra X4250 server on which you want to install the operating system.
-
At the login screen, enter a user name and countersign for an account that has administrator privileges.
The ILOM master menu screen appears.
-
Ready the session timeout:
-
From the chief menu, click the Arrangement Information tab.
The Arrangement Information submenu tabs announced.
-
Click the Session Time-Out submenu tab.
The Session Time-Out screen appears.
-
Select 3 hours, and then click Employ.
-
-
From the primary menu, click the Remote Command tab.
The Remote Control screen appears.
-
Click the Redirection tab.
The Redirection screen appears with a Launch Redirection button.
-
Click the Launch Redirection push button.
A JavaRconsole screen appears asking "Do you want to run the awarding?".
-
Click the Run push.
The Sun ILOM Remote Console screen is displayed.
-
On the Sun ILOM Remote Console screen, click the Device tab and select CD‐ROM.
The CD-ROM Choice screen is displayed.
-
Cull or blazon the CD-ROM drive that you are using to install the OS.
-
Insert the Operating System CD/DVD to be installed on the Dominicus Netra X4250 server into the local CD/DVD drive.
Note - The LSI RAID drivers should be installed on the server. Come across Installing the Drivers to install the LSI drivers.
-
Reboot the server:
-
Click the Remote Control tab on the Sun ILOM screen'southward main menu.
-
Click the Remote Ability Control tab and select Reset from the Select Activity menu.
-
Click on the Save push button.
The server boots from the virtual CD.
-
Running Windows Update
Installing Windows Server 2003 for a RAID Configuration
The Sun Netra X4250 Tools and Drivers DVD contains the following drivers:
-
Intel® NIC drivers
-
Intel chipset drivers
-
AST2000 video drivers
-
LSI SAS3081E-R RAID drivers
-
TPM drivers
The server supports the LSI SAS3081E-R RAID bill of fare. Apply these procedures to install Windows Server 2003 with a RAID configuration:
Method | Section or Procedure |
---|---|
Install Windows Server 2003 using a Reburn CD created with Solaris or Linux. | To Install Windows Server 2003 Using a Reburn CD Containing LSI Drivers |
Install Windows Server 2003 using a driver diskette. | To Install Windows 2003 Using a Driver Diskette |
To Install Windows Server 2003 Using a Reburn CD Containing LSI Drivers |
The Tools and Drivers DVD contains a script that enables you to create a new Windows Server 2003 CD with the necessary LSI drivers. After creating the new CD, you can boot from the CD and install Windows Server 2003 in the usual way. This CD automatically installs the drivers.
For specific and current data near the 2003 Reburn script, see the description at the top of the script, which is located in /utilities/REBURN on the Tools and Drivers DVD.
You need the following:
-
A organisation running Solaris Operating System for x86 Platforms, Ruby-red Hat Enterprise Linux five, or SUSE Linux Enterprise Server (SLES) 10
-
A CD burner and a blank CD-R or CD-RW
-
A Windows Server 2003 CD (retail media just – not an OEM version)
-
The latest Sun Netra X4250 Server Tools and Drivers DVD
-
On a Solaris x86, RHEL 5, or SLES 10 system, insert the Sun Netra X4250 Server Tools and Drivers DVD into a DVD drive.
-
Log in as root (superuser).
-
Create a temporary directory with at least 1.2 GByte of infinite.
For example:
# mkdir /files
-
Copy the 2003REBURN_ version .zip file to that directory.
where version is the current version of 2003Reburn.
For example:
# cp /utilities/REBURN/2003reburn_Linux/2003Reburn_1.iii.2.cypher /files
-
Squirt the Tools and Drivers DVD and insert your retail Windows 2003 32-bit CD.
-
Change to the directory that you copied the .zip file to in Footstep iv.
-
Unzip the 2003Reburn_ version .nothing file.
For example:
# unzip -q 2003Reburn_1.iii.ii.zip
-
Run the 2003Reburn script.
For example:
# ./files/2003Reburn -b
Notation - If your system does not have the ability to fire CDs, type the command without the -b option. An ISO image is created, which you can relieve to a system that has a CD burner.
The script displays the commuter files it expects to be located in the current directory. When the iv commuter files or have been downloaded into that directory, the script creates a new ISO prototype and then automatically burns that ISO paradigm onto a CD (if the organization has a CD burner).
-
Later you create the CD, install Windows Server 2003 on the Dominicus Netra X4250 server, using the newly created CD.
-
When the OS installation is complete, install the display and chipset drivers as explained in Installing the Drivers .
Note - Installing with the Windows Server 2003 Reburn CD does not let for the power to team the NICs. To team the NICs, run the OS-specific *.bat file located in the /DRIVERS/WINDOWS/IntelNIC/ on the Tools and Drivers DVD: windows_1a32_install.bat or windows_x64_install.bat
To Create an LSI SAS3081E-R RAID Drivers Boot Diskette |
This procedure describes how to create an LSI drivers kick diskette in training for installing Windows Server 2003.
Note - This procedure requires a USB diskette drive. |
-
Copy drivers from the Tools and Drivers DVD to the diskette bulldoze:
# /DRIVERS/WINDOWS/RAID/LSI/MSM/ USB floppy
-
Attach a USB diskette drive to the Sun Netra X4250 server.
-
On a Windows system, insert the Dominicus Netra X4250 Server Tools and Drivers DVD.
-
Insert a blank diskette into the Windows system.
-
Copy the contents of the MSM directory on the Tools and Drivers DVD to the diskette:
> Copy d: \DRIVERS\WINDOWS\RAID\LSI\MSM\ a:
To Install Windows Server 2003 Using the LSI SAS3081E-R Driver Diskette |
This procedure describes how to use the LSI SAS3081E-R commuter diskette to install the Windows Server 2003 Os.
-
Attach a USB diskette drive to the Sun Netra X4250 server.
-
Insert a Windows Server 2003 32-fleck or 64-flake installation DVD into the DVD bulldoze.
-
Press the F6 key to install the third-party RAID driver.
-
Press the S key to specify additional drivers, and insert the diskette.
-
Select LSI Logic Fusion-MPT SAS Commuter (Server 2003), and then press Enter.
-
To continue the Windows Server 2003 installation, press Enter.
-
When the Bone installation is finished, install the drivers as explained in Installing the Drivers .
Installing the Drivers
The following sections describe how to install the drivers from the Tools and Drivers DVD. Choose one of the following procedures to install the drivers:
Method | Department or Procedure |
---|---|
Use KVMS Over IP to install the drivers. | To Install the Drivers Using Remote KVMS |
Install the drivers using the on-lath DVD. | To Install the Drivers Direct Onto the Sun Netra X4250 Server |
Annotation - If y'all used the 2003Reburn choice to create a Windows Server 2003 CD that contains the drivers, the drivers are installed during the OS installation. |
To Install the Drivers Straight Onto the Lord's day Netra X4250 Server |
If your server has an on-board DVD drive, you can install the drivers direct onto the server, using the Sun Netra X4250 Server Tools and Drivers DVD.
-
Insert the Sun Netra X4250 Server Tools and Drivers DVD into the DVD drive.
-
To install the chipset drivers, double-click the executable file:
d:\DRIVERS\WINDOWS\Chipset
-
To install the Ethernet drivers, do i of the following:
-
Install the drivers using the installation sorcerer:
a. Double-click the .bat file and follow the installation wizard.
b. When the wizard is washed, go to Footstep 4.
-
Install the drivers using the Windows Device Manager:
a. Open the Device Director.
b. Correct-click the NIC with a xanthous assertion signal and choose Update.
c. Select No, non at this time and click Adjacent.
d. Select Install from a Listing or Specific Location and click Next.
e. Click Browse and point to the NIC driver on the CD/DVD path:
d:\DRIVERS\WINDOWS\IntelNIC
f. Click OK.
k. When the installation is done, go to Stride iv.
-
-
To install TPM drivers, extract the .zip file from d:\DRIVERS\WINDOWS\TPM.
-
Double-click the executable.
-
Follow the installation wizard to install TPM drivers.
-
-
To install the AST2000 display drivers, open up the Windows Device Manager and update the device driver every bit follows:
-
Correct-click the display commuter and choose Update.
The Hardware Update Sorcerer appears.
-
Select No, not at this fourth dimension and click Next.
-
In the next dialog box, select Install from a list or specific location and click Adjacent.
-
Click Browse and change to the post-obit directory on the Tools and Drivers DVD:
D:\DRIVERS\WINDOWS\Display\[2003_32|2003_64]
-
Click OK then click Next.
The AST2000 driver is installed.
-
-
Reboot the server.
Installing RAID Management Utility Software for Windows Server 2003
Windows Server 2003 RAID Management Utility Software is available for the LSI SAS3081E-R controller cards. This section contains a procedure for installing the utility software on the LSI SAS3081E-R controller carte du jour.
To Install the LSI RAID Management Utility Software for Windows Server 2003 |
Utilize this procedure to install the RAID Direction Utility Software for a server equipped with an LSI SAS3081E-R controller card.
-
Insert the Tools and Drivers DVD into the server'due south DVD drive.
-
Use the Windows file browser to navigate to the /DRIVERS/WINDOWS/RAID/LSI/MSM directory on the Tools and Drivers DVD.
-
To first the LSI RAID Management Utility Software installation magician, double-click the executable (.exe) file.
-
To install the software, follow the installation wizard.
Copyright © 2010, Oracle and/or its affiliates. All rights reserved.
Source: https://docs.oracle.com/cd/E19790-01/820-4602-11/chapter5.html
Posted by: gonzalesandlever.blogspot.com
0 Response to "How To Install Windows Server 2003 R2"
Post a Comment